PQ200 Screen2

The BGI PQ200 FRM Sampler uses BGI pioneering technology to meet and exceed the requirements for ambient particulate sampling dictated by the U.S Environmental Protection Agency. This includes the design of reliable PM10, PM2.5 and PM1 Inlets, volumetric sample flow rate control, data logging and software for report and data processing.

  • Portable sampler for TSP, PM10, PM2.5, PM Coarse, and PM1
  • EPA Reference Method for PM10 sampling (Designation No. RFPS-1298-125)
  • EPA PM2.5 Reference Method sampler (Designation No. RFPS-0498-116)
  • EPA PM Coarse approved sampler
  • Only designated reference sampler capable of a 24 hour run on internal built-in 12 volt battery. Internal battery provides power during AC power outages meaning you never have sample interruptions.
  • Ordered by EPA as the PEP Audit Reference Method
  • Only designated Reference Method sampler with solar power option
  • Optional solar panel can allow for indefinite operation without charging or connection to an AC power source

PQ200 Specifications

  • Particle Size: PM10, PM2.5, PM1, TSP
  • Flow Range: 10-20 LPM
  • US EPA Designation: EPA RFPS-1298-125 FRM for PM10, EPA RFPS-0498-116 FRM for PM2.5, EPA RFPS-1208-173 FRM for PM10-2.5
  • Sampling Interval: 24-Hour Sampling
  • Pump: Dual Diaphragm Vacuum Pump
  • Automatic, multi-point flow calibration using the deltaCal calibrator
  • Accuracy: ±2%
  • Operating Temperature: -30 to 50° C
  • Ambient/Filter Temperature Sensor Resolution: 0.1° C
  • Temperature Sensors Accuracy: ±0.16° C
  • Barometric Pressure Sensor: 545 to 800 mmHg
  • Easily calibrate temperature/pressure through simple-to-navigate menu
  • Internal Battery: 12V 18Ah
  • Optional: Solar
  • Data Output: RS232 & USB Connection
  • Interface: Push-button
  • Language Options: English, Spanish
  • USB connectivity for easier data download via portable flash drive
  • Ability to upgrade firmware automatically via flash drive
  • Diagnostic log file to retrace conditions

Applications

  • Ambient Particulate Federal Reference Method (FRM) Sampling
  • PM2.5 FRM with Solar Approval
  • (RFPS-1298-125) PM10 FRM, (RFPS-0202-116) PM2.5 VSCC, (RFPS-0498-116) PM Coarse
  • Fence Line Monitoring
  • Remediation Projects
  • Remote Site Monitoring

Features

  • Single channel design for maximum reliability and portability
  • Friendly operator interface and easy data collection and downloading
  • Includes built-in 12-volt DC battery power system charger (U.L. approved), allows operation for up to 30 hours
  • Advanced flow control system
  • Download software included

Accessories

  • Solar Panel
  • Test Cassette
  • Cassette Transport Case
  • Cassette Opener
  • tetraCal or deltaCal flow calibrators

PQ200 Performance Checks